Infrared Thermometers
JD-10 Non-Contact Infrared Thermometer – 800°C Industrial Temperature Measurement
JD-10 non-contact infrared thermometer with -50°C to 800°C range, 12:1 optics and adjustable emissivity. Explore specifications and bulk supply from ZYD.
JD-10 Non-Contact Infrared Thermometer – 800°C Industrial Temperature Measurement
-50°C to 800°C | 12:1 Distance-to-Spot Ratio | Adjustable Emissivity | 0.5s Response Time
Product Overview
The JD-10 Non-Contact Infrared Thermometer is a handheld temperature measuring instrument designed for quick surface temperature checks during industrial maintenance, HVAC servicing, electrical equipment inspection, and general troubleshooting.
With a wide measurement range of -50°C to 800°C (-58°F to 1472°F), the JD-10 allows technicians to check surface temperatures without direct physical contact.
Its 12:1 distance-to-spot ratio supports measurement from a distance, while adjustable emissivity (0.10–0.99) helps users adapt the instrument to different surface materials.
Featuring a 0.5-second response time, LCD display, and automatic power-off, the JD-10 offers practical functionality for routine temperature inspection and maintenance work.
Key Features and Practical Benefits
1. Wide Temperature Range: -50°C to 800°C
Measure a broad range of surface temperatures, from refrigeration equipment to elevated-temperature industrial components.
Practical Benefit: One instrument can support various surface temperature inspection tasks across maintenance and servicing applications.
2. Non-Contact Surface Temperature Measurement
The JD-10 measures infrared radiation emitted by a target surface, allowing temperature checks without physical contact.
Practical Benefit: Useful for checking hot surfaces, accessible equipment components, and areas where contact measurements may be inconvenient.
3. 12:1 Distance-to-Spot Ratio
The 12:1 optical ratio indicates how the measurement spot changes with distance.
For example, at a distance of approximately 120 cm, the nominal measurement spot is approximately 10 cm in diameter. The target should be larger than the measurement spot to reduce interference from surrounding surfaces.
Practical Benefit: Helps technicians select a suitable measurement distance when checking different equipment surfaces.
4. Adjustable Emissivity: 0.10–0.99
Surface materials differ in their ability to emit infrared radiation.
The adjustable emissivity function allows users to select appropriate settings for different materials and surface finishes.
Practical Benefit: Supports more appropriate temperature measurements across different surfaces when the correct emissivity setting and measurement technique are used.
5. Fast 0.5-Second Response
The instrument provides a manufacturer-specified response time of 0.5 seconds.
Practical Benefit: Helps technicians perform quick spot checks and compare temperatures across multiple inspection points.
6. LCD Display and Temperature Indication
The LCD displays temperature readings and provides Hi/Lo indications for readings outside the supported measurement range.
7. Automatic Power-Off and Portable Design
Powered by two AAA batteries, the JD-10 automatically switches off after approximately 15 seconds of inactivity.
Its handheld design is convenient for on-site maintenance, workshop use, and routine equipment inspections.
Typical Applications
HVAC and Refrigeration Maintenance
Check surface temperatures on accessible components of air conditioning, heating, ventilation, and refrigeration systems.
Typical tasks include investigating abnormal surface temperature differences and performing routine equipment checks.
Electrical Equipment Maintenance
Check accessible surface temperatures around electrical enclosures, connections, and equipment housings as part of preliminary overheating investigations.
Measurement results should be evaluated with consideration for surface emissivity, reflections, and operating conditions.
Industrial Machinery Inspection
Perform spot temperature measurements on machinery housings, motor surfaces, and other accessible components during routine maintenance.
Automotive Maintenance
Check accessible surface temperatures around engine components, cooling systems, and exhaust-related parts to support maintenance inspections.
Manufacturing and Workshop Applications
Support surface temperature checks during production processes, workshop activities, and equipment servicing.
Technical Specifications
Parameter | Specification |
|---|---|
Model | JD-10 |
Product Type | Non-Contact Infrared Thermometer |
Temperature Range | -50°C to 800°C (-58°F to 1472°F) |
Accuracy | To Be Confirmed |
Repeatability | 1% or 1°C (Manufacturer-Stated) |
Response Time | 0.5 seconds |
Emissivity | Adjustable, 0.10–0.99 |
Distance-to-Spot Ratio | 12:1 |
Spectral Response | 8–14 µm |
Display | LCD |
Overrange Indication | Hi / Lo |
Low Battery Indication | Supported |
Automatic Power-Off | Approx. 15 seconds |
Power Supply | 2 × AAA Batteries |
Operating Temperature | 0°C to 50°C |
Operating Humidity | 10–95% RH, Non-Condensing |
Storage Temperature | -20°C to 50°C |
Measurement accuracy and repeatability conditions should be confirmed against the manufacturer's complete technical specifications.
Important Measurement Considerations
For more reliable infrared temperature readings:
- Ensure the target surface is larger than the measurement spot.
- Select an appropriate emissivity value for the measured material.
- Be aware that polished or highly reflective surfaces can produce misleading readings.
- Consider distance, surrounding temperature, and surface conditions when interpreting results.
- Use a suitable contact temperature probe when the application requires direct measurement of internal or fluid temperatures.
Frequently Asked Questions
Q1: What is the JD-10 infrared thermometer used for?
The JD-10 is designed for non-contact surface temperature measurement in applications such as HVAC maintenance, industrial equipment inspection, electrical servicing, and automotive troubleshooting.
Q2: Can the JD-10 measure temperatures up to 800°C?
Yes. Its manufacturer-specified temperature measurement range is -50°C to 800°C. Measurement accuracy at different temperatures should be checked against the complete technical specifications.
Q3: What does the 12:1 distance-to-spot ratio mean?
It describes the relationship between measurement distance and the approximate diameter of the measured area. As the distance increases, the measurement spot becomes larger.
Q4: Why is adjustable emissivity important?
Different surfaces emit infrared energy at different rates. Adjustable emissivity helps users match the instrument settings to the material being measured, improving the suitability of the measurement setup.
Q5: Is this infrared thermometer suitable for industrial maintenance?
The JD-10 can support routine surface temperature inspections on accessible industrial equipment. Buyers should confirm that its measurement range, accuracy, and operating conditions meet their specific application requirements.
Q6: Can the JD-10 measure human body temperature?
The JD-10 is intended for general surface temperature measurement and is not presented as a clinical body-temperature measuring instrument.
Product Supply for Distributors and Industrial Buyers
Shenzhen Zhanyueda Technology Co., Ltd. (ZYD) supplies test and measurement instruments to international importers, distributors, industrial equipment suppliers, and private-label brands.
The JD-10 is suitable for consideration in product ranges serving HVAC maintenance, electrical servicing, industrial maintenance, and general temperature measurement applications.
For purchasing inquiries, our team can help confirm:
- Product specifications and available documentation
- Sample availability and bulk pricing
- Packaging and private-label options
- Order quantities and delivery arrangements
Interested in adding the JD-10 to your product range?
Contact ZYD to discuss your market requirements and purchasing needs.